Directional Control Valves

Filter
Showing 1581 - 1590 of 5082 items
  • Standard and F11 Water Glycol-Based Fluid
  • 3-Position Spring-Centered Spool
  • 30*1L/min. Max Flow, 0.5*1L/min. Min Flow
  • External Pilot, Internal Drain Options
  • Various Mounting Dimensions
  • Replacement actuator for EP Series
  • Tokyo Keiki (formerly TOKIMEC)
  • ISO 4401-AE-08-4-A (Size 06)
  • Max Working Pressure: 31.5 MPa
  • Max Flow: per Pressure-Flow Characteristics
  • Allowable Tank Port Back Pressure: 20.6 MPa
  • Min. Pilot Pressure: per Min Pilot Pressure Curves
  • Max Pilot Pressure: 31.5 MPa
  • Weight (Single Solenoid): 20.04 kg
  • Weight (Double Solenoid): 20.64 kg
  • Reduced power consumption 
  • Direct connection to PLCs 
  • Wide range of compatible hydraulic fluids 
  • Low-holding current operation for extended valve life 
  • Standard or left-hand build for flexibility 
  • Plug-in solenoids for easy installation 
  • Sink or source contact point input for compatibility with different control systems.
  • COM-3-2C-30-PH1-30 | Directional Control and Flow Valve COM-3-2C-30-PH1-30 | Directional Control and Flow Valve
    20%
    • Standard and F11 Water Glycol-Based Fluid
    • 3-Position Spring-Centered Spool
    • 30*1L/min. Max Flow, 0.5*1L/min. Min Flow
    • External Pilot, Internal Drain Options
    • Various Mounting Dimensions
    $ 23,509.00
    $ 29,386.00

    Replacement DC24V coil for Tokyo Keiki (formerly Tokimec) DG4V-3 Solenoid Operated Directional Control Valves

    •  DC24V
    • +10%/-15%, Allowable Voltage Tolerance
    • Holding Current: 1.16A

    Replacement AC110V / AC120V coil for Tokyo Keiki (formerly Tokimec) DG4V-3 Solenoid Operated Directional Control Valves

    •  AC110V (50Hz) / AC115V/AC120V (60Hz)
    • +10%/-15%, Allowable Voltage Tolerance
    • Initial Current: 2.0A-2.10A (60Hz) / 2.20A (50Hz)
    • Holding Wattage: 21.0W-23.0W (60Hz) / 22.0W (50Hz) 

    Replacement AC100V / AC110V coil for Tokyo Keiki (formerly Tokimec) DG4V-3 Solenoid Operated Directional Control Valves

    •  AC100V (50/60Hz) / AC110V (60Hz)
    • +10%/-15%, Allowable Voltage Tolerance
    • Initial Current: 2.10A (60Hz) / 2.42A (50Hz) / 2.32A (60Hz)
    • Holding Wattage: 19.0W (60Hz) / 22.0W (50Hz) / 23.0W (60Hz)

    Replacement DC12V coil for Tokyo Keiki (formerly Tokimec) DG4V-3 Solenoid Operated Directional Control Valves

    •  DC12V
    • +10%/-15%, Allowable Voltage Tolerance
    • Holding Current: 2.36A

    Replacement DC24V coil for Tokyo Keiki (formerly Tokimec) DG4V-3 Solenoid Operated Directional Control Valves

    •  DC24V
    • +10%/-15%, Allowable Voltage Tolerance