{"product_id":"jf-g03-105-16-77-flow-control-valve","title":"JF-G03-105-16-77 | Flow Control Valve","description":"\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003eThe \u003cb\u003e\u003ca href=\"https:\/\/www.cascadeindustrial.com\/search?type=product\u0026amp;options%5Bunavailable_products%5D=show\u0026amp;options%5Bprefix%5D=last\u0026amp;q=Daikin\"\u003eDaikin\u003c\/a\u003e \u003ca href=\"https:\/\/www.cascadeindustrial.com\/search?type=product\u0026amp;options%5Bunavailable_products%5D=show\u0026amp;options%5Bprefix%5D=last\u0026amp;q=Flow+Control+Valve\"\u003eFlow Control Valve with Check Valve\u003c\/a\u003e\u003c\/b\u003e is designed for precise and reliable flow regulation while compensating for pressure and temperature changes. This helps maintain a consistent set flow rate even when load pressure or oil temperature varies. The integrated check valve supports controlled fluid flow and dependable hydraulic system performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003eIdeal for hydraulic applications requiring accurate flow adjustment, this \u003cb\u003eDaikin Flow Control Valve\u003c\/b\u003e features an easy-to-use flow regulating handle. The handle can be rotated through four cycles, allowing small adjustments and simple resetting of the flow setting. Optional configurations are available with a handle locking key or a structure designed to help prevent handle jumping.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-outline-level: 3;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003eBrand:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003e Daikin\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003eModel Series:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003e JF\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003eCheck Valve:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003e Available\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003eNominal Diameter:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003e 1\/4\" or 3\/8\"\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003eMaximum Operating Pressure:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003e 21 MPa (210 kgf\/cm²)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003eMaximum Flow Rate:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003e 30 L\/min (1\/4\") or 105 L\/min (3\/8\")\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003eCheck Valve Cracking Pressure:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003e 0.035 MPa (0.35 kgf\/cm²)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003eConnection:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003e Gasket-attached type\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal; mso-list: l0 level1 lfo1; tab-stops: list .5in;\"\u003e\n\u003cb\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003eWeight:\u003c\/span\u003e\u003c\/b\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003e Approximately 3.9 kg (1\/4\") or 8.3 kg (3\/8\")\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\" style=\"mso-margin-top-alt: auto; mso-margin-bottom-alt: auto; line-height: normal;\"\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003eThe \u003cb\u003e\u003ca href=\"https:\/\/www.cascadeindustrial.com\/search?type=product\u0026amp;options%5Bunavailable_products%5D=show\u0026amp;options%5Bprefix%5D=last\u0026amp;q=Daikin\"\u003eDaikin\u003c\/a\u003e \u003ca href=\"https:\/\/www.cascadeindustrial.com\/search?type=product\u0026amp;options%5Bunavailable_products%5D=show\u0026amp;options%5Bprefix%5D=last\u0026amp;q=Flow+Control+Valve\"\u003eFlow Control Valve\u003c\/a\u003e\u003c\/b\u003e provides pressure- and temperature-compensated flow regulation for consistent performance in hydraulic systems. Its adjustable handle allows precise flow setting and easy resetting, while optional locking and anti-jump features provide additional control and stability. With multiple nominal diameter and flow-rate options, the JF series can accommodate different hydraulic flow control requirements. \u003ca href=\"https:\/\/www.cascadeindustrial.com\/pages\/about-us\"\u003e#CascadeIndustrial\u003c\/a\u003e \u003ca href=\"https:\/\/www.cascadeindustrial.com\/search?type=product\u0026amp;options%5Bunavailable_products%5D=show\u0026amp;options%5Bprefix%5D=last\u0026amp;q=Daikin\"\u003e#Daikin\u003c\/a\u003e \u003ca href=\"https:\/\/www.cascadeindustrial.com\/search?type=product\u0026amp;options%5Bunavailable_products%5D=show\u0026amp;options%5Bprefix%5D=last\u0026amp;q=Flow+Control+Valve\"\u003e#FlowControlValve \u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"mso-fareast-font-family: 'Times New Roman'; mso-bidi-font-family: Calibri; mso-bidi-theme-font: minor-latin;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0746\/8325\/3052\/files\/1_6f9d44f4-3fea-4fb5-b871-f480b9d92cba_2048x2048.png?v=1786978599\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0746\/8325\/3052\/files\/2_8d5388df-0581-4fa4-aed1-a1bed5a06e61_2048x2048.png?v=1786978603\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","brand":"Daikin","offers":[{"title":"Default Title","offer_id":53996252954940,"sku":"JF-G03-105-16-77","price":1533.0,"currency_code":"CAD","in_stock":true}],"url":"https:\/\/www.cascadeindustrial.com\/en-ca\/products\/jf-g03-105-16-77-flow-control-valve","provider":"Cascade Industrial Services Corp","version":"1.0","type":"link"}